ROXELL -
031 - 0516
FLEX- AUGER - INSTALLATION INSTRUCTIONS
III- 64
WIRING DIAGRAM AUTOMATIC OUTLET
Feedback of OPEN/CLOSE signal by digital input or relay.
Both signals OPEN & CLOSE which come from the Automatic Drop can be connected to a 24 VDC relay.
In MFII application the feedback can be directly connected to a IDM.
Declaration signalling LED
24VDC+Close
LED Blue
Motor OPEN
LED Blue blink
Motor Alarm
LED Red
Motor Calibration
LED Green
With blocking motor alarm LED Red
Remove DROP.
Remove possible blocked feed.
Switch 24VDC OFF.
Switch 24VDC ON.
Calibration starts automatically.
LED Blue
Technical specifications
Voltage
24 VDC
20%
Motor Current Stand-by
20 mA
Motor Current OPEN/CLOSE
150 mA
Motor Current Alarm
400 mA
Relais output 24VDC
100 mA
Max. Cable Length
200 M
Min. Cable Section
0.5mm
2
max.100 M
Min. Cable Section
0.75mm
2
max. 200 M
Remark
After interruption of voltage in “OPEN position, the input will not be noticed for a 15 sec. period, so the
“OPEN position" retains for 15 sec..
THE AUTOMATIC OUTLET STARTS AUTOMATICALLY. NEVER PUT YOUR HANDS IN
THE OUTLET OR IN THE DROP HOLE BEFORE MAKING SURE THAT THE CURRENT
IS SWITCHED OFF.
DANGER
ATTENTION : Contact ROXELL for professional advice when using following feeds:
CCM (Corn Cob Mix).
Feed mixed with CCM.
Soya.
Soya lumps.
Wet feed.
Without explicite authorization, all our warranties will expire and no claims will be accepted.
Also contact Roxell if you want to use strongly grating feeds like hen feed etc...
Summary of Contents for FLEX-AUGER FA 125
Page 6: ......
Page 11: ...I 1 PART I INSTRUCTIONS FOR THE USER ...
Page 12: ...FLEX AUGER INSTRUCTIONS FOR THE USER ROXELL 031 0516 I 2 ...
Page 24: ...ROXELL 031 0516 FLEX AUGER COMPONENTS II 2 FIGURE 1 GENERAL VIEW ...
Page 86: ...ROXELL 031 0516 FLEX AUGER COMPONENTS II 64 GENERAL LAY OUT OVERHEAD SYSTEM FIGURE 5 A B C ...
Page 96: ......
Page 97: ...III 1 PART III INSTALLATION INSTRUCTIONS ...
Page 98: ...ROXELL 031 0516 FLEX AUGER INSTALLATION INSTRUCTIONS III 2 ...
Page 100: ...ROXELL 031 0516 FLEX AUGER INSTALLATION INSTRUCTIONS III 2 FIGURE 1 GENERAL VIEW ...
Page 166: ...ROXELL 031 0516 FLEX AUGER INSTALLATION INSTRUCTIONS III 68 FIGURE 135 ...
Page 177: ......