ROXELL -
031 - 0516
FLEX- AUGER - INSTALLATION INSTRUCTIONS
III- 50
If bins do not have the same capacity : make sure
that bin A is the smallest.
A
B
Maximum center distance
between both bins : 4m.
FIGURE 112.
Minimum
distance
TO INSTALL THE RETURN TANDEM SYSTEM (MODEL 75 & 90)
Fix the tube to the intake boot.
Do not fix the intake boot to the upper boot at this stage !
FIGURE 113.
DETERMINE LENGTH OF TUBE BETWEEN BOTH BINS.
Close slide of bin B.
Open slide of bin A with the tandem intake
boot.
Adjust flow regulator 1 in the intake boot until
the system runs without overload and/or until
you get the required capacity.
Close slide of bin A and open slide of bin B.
Now adjust flow regulator 2 so that the feed
flow from B to A is slightly lower than the Flex-
Auger system feed flow. That way no obstruc-
tion will occur.
Position X = the highest capacity.
FIGURE 114.
TO INSTALL THE FLOW REGULATOR
A
B
Summary of Contents for FLEX-AUGER FA 125
Page 6: ......
Page 11: ...I 1 PART I INSTRUCTIONS FOR THE USER ...
Page 12: ...FLEX AUGER INSTRUCTIONS FOR THE USER ROXELL 031 0516 I 2 ...
Page 24: ...ROXELL 031 0516 FLEX AUGER COMPONENTS II 2 FIGURE 1 GENERAL VIEW ...
Page 86: ...ROXELL 031 0516 FLEX AUGER COMPONENTS II 64 GENERAL LAY OUT OVERHEAD SYSTEM FIGURE 5 A B C ...
Page 96: ......
Page 97: ...III 1 PART III INSTALLATION INSTRUCTIONS ...
Page 98: ...ROXELL 031 0516 FLEX AUGER INSTALLATION INSTRUCTIONS III 2 ...
Page 100: ...ROXELL 031 0516 FLEX AUGER INSTALLATION INSTRUCTIONS III 2 FIGURE 1 GENERAL VIEW ...
Page 166: ...ROXELL 031 0516 FLEX AUGER INSTALLATION INSTRUCTIONS III 68 FIGURE 135 ...
Page 177: ......