Motor Power (kW)
Net voltage
Protection
Max. cable length (m)
Wire gauge (mm²)
0.75
1x230V 50Hz
GV2ME10
0 - 44
1.5
45 - 73
2.5
74 - 117
4
3x230V 50Hz
GV2ME08
0 - 69
1.5
70 - 116
2.5
117 - 185
4
3x400V 50Hz
GV2ME07
0 - 197
1.5
198 - 328
2.5
329 - 525
4
0.9
1x220V 60Hz
1x230V 60Hz
GV2ME14
0 - 26
1.5
27 - 44
2.5
45 - 71
4
3x220V 60Hz
3x230V 60Hz
GV2ME10
0 - 42
1.5
43 - 70
2.5
71 - 113
4
3x380V 60Hz
3x400V 60Hz
GV2ME08
0 - 117
1.5
118 - 196
2.5
197 - 314
4
1.1
3x230V 50Hz
GV2ME10
0 - 44
1.5
45 - 73
2.5
74 - 117
4
3x400V 50Hz
GV2ME08
0 - 123
1.5
124 - 205
2.5
206 - 328
4
1.32
3x220V 60Hz
3x230V 60Hz
GV2ME14
0 - 26
1.5
27 - 44
2.5
45 - 71
4
3x380V 60Hz
3x400V 60Hz
GV2ME08
0 - 117
1.5
118 - 196
2.5
197 - 314
4
1.5
1x230V 50Hz
GV2ME14
0 - 27
1.5
28 - 46
2.5
47 - 74
4
3x230V 50Hz
GV2ME10
0 - 44
1.5
45 - 73
2.5
74 - 117
4
3x400V 50Hz
GV2ME08
0 - 123
1.5
124 - 205
2.5
206 - 328
4
1.8
3x220V 60Hz
3x230V 60Hz
GV2ME14
0 - 26
1.5
27 - 44
2.5
45 - 71
4
3x380V 60Hz
3x400V 60Hz
GV2ME10
0 - 74
1.5
75 - 124
2.5
125 - 199
4
2.2
3x230V 50Hz
GV2ME14
0 - 27
1.5
28 - 46
2.5
47 - 74
4
3x400V 50Hz
GV2ME10
0 - 78
1.5
79 - 130
2.5
130 - 208
4
2.64
3x380V 60Hz
3x400V 60Hz
GV2ME14
0 - 47
1.5
48 - 78
2.5
79 - 125
4
In reality, if the cable lengths are longer than the ones given in the tables above, then you have to take one of
the following actions:
- Double the section of the PE (earth connection)
- Increase the section of the phases AND the PE (earth connection)
- Place a earth-leak circuit breaker
Summary of Contents for FLEX-AUGER FA 125
Page 6: ......
Page 11: ...I 1 PART I INSTRUCTIONS FOR THE USER ...
Page 12: ...FLEX AUGER INSTRUCTIONS FOR THE USER ROXELL 031 0516 I 2 ...
Page 24: ...ROXELL 031 0516 FLEX AUGER COMPONENTS II 2 FIGURE 1 GENERAL VIEW ...
Page 86: ...ROXELL 031 0516 FLEX AUGER COMPONENTS II 64 GENERAL LAY OUT OVERHEAD SYSTEM FIGURE 5 A B C ...
Page 96: ......
Page 97: ...III 1 PART III INSTALLATION INSTRUCTIONS ...
Page 98: ...ROXELL 031 0516 FLEX AUGER INSTALLATION INSTRUCTIONS III 2 ...
Page 100: ...ROXELL 031 0516 FLEX AUGER INSTALLATION INSTRUCTIONS III 2 FIGURE 1 GENERAL VIEW ...
Page 166: ...ROXELL 031 0516 FLEX AUGER INSTALLATION INSTRUCTIONS III 68 FIGURE 135 ...
Page 177: ......