ROXELL -
031 - 0516
FLEX- AUGER - INSTALLATION INSTRUCTIONS
III- 56
TO INSTALL THE SENSOR ON A FLAT SURFACE
Flat surface
Hole
Ø
48
Sensor
Electrical connection : see Fig. 122.
Connection box
FIGURE 122.
Drill a hole dia. 32
Sensor end.
Fix sensor holder with 2
clamps.
FIGURE 123.
32
TO INSTALL THE SENSOR ON A DROP TUBE
INSTALL THE SENSOR AS HIGH AS POSSIBLE (A ”MUST” WITH BRIDOMAT).
DO NOT INSTALL THE SENSOR IN THE FEED FLOW (HOUSING MAY WEAR OUT).
Delay.
Grey
Yellow
Brown
Status led
Lamp
2 A
2 4 0 V
4
3
1
4 -1 2 m m
1 s e c .- 1 0 m in
.
Standard position : 5 sec/5mm.
230V
Cable
Black
Remove protection screw
before adjustment
Blue
Distance
03101185 : SENSOR
.
VC12
03101193 : SENSOR VC11
Supply
When supply
off
Adjustment
screw
Protection
screw
CONNECTION
FIGURE 124.