ROXELL -
031 - 0516
FLEX- AUGER - INSTALLATION INSTRUCTIONS
III- 29
FIGURE 41.
FIGURE 42.
Use a hole saw.
Make holes well aligned per tube.
Option : if you only have a hand saw or a grinder
available, make square holes in the tubes.
DIAMETER
TO MAKE THE DROP HOLES IN THE TUBES
DROP HOLE DIMENSIONS
FLEX AUGER
DIAMETER
L X W
MODEL 55
40MM
40MM X 40 MM
MODEL 75
60MM
60MM X 60MM
MODEL 90
76MM
76MM X 76MM
MODEL 125
108MM
108MM X 108MM
MAKE SURE THAT HOLES IN A TUBE ARE IN A STRAIGHT LINE.
IF YOU HAVE TWO ROWS OF FEEDING TROUGHS : INSTALL OUTLETS IN PAIRS AT
THE FOLLOWING DISTANCES :
FLEX AUGER
MINIMUM DISTANCE
BETWEEN HOLES (X)
FIGURE 43.
MODEL 55
106mm
MODEL 75
116mm
MODEL 90
125mm
MODEL 125
250mm
HOLE FOR MAXIMUM FEED DROP OUT
FLEX AUGER
MAX. HOLE
LENGTH (L)
MAX. HOLE WIDTH
(W)
FIGURE 44.
MODEL 55
70mm
40mm
MODEL 75
80mm
60mm
MODEL 90
80mm
76mm
MODEL 125
108mm
108mm
Summary of Contents for FLEX-AUGER FA 125
Page 6: ......
Page 11: ...I 1 PART I INSTRUCTIONS FOR THE USER ...
Page 12: ...FLEX AUGER INSTRUCTIONS FOR THE USER ROXELL 031 0516 I 2 ...
Page 24: ...ROXELL 031 0516 FLEX AUGER COMPONENTS II 2 FIGURE 1 GENERAL VIEW ...
Page 86: ...ROXELL 031 0516 FLEX AUGER COMPONENTS II 64 GENERAL LAY OUT OVERHEAD SYSTEM FIGURE 5 A B C ...
Page 96: ......
Page 97: ...III 1 PART III INSTALLATION INSTRUCTIONS ...
Page 98: ...ROXELL 031 0516 FLEX AUGER INSTALLATION INSTRUCTIONS III 2 ...
Page 100: ...ROXELL 031 0516 FLEX AUGER INSTALLATION INSTRUCTIONS III 2 FIGURE 1 GENERAL VIEW ...
Page 166: ...ROXELL 031 0516 FLEX AUGER INSTALLATION INSTRUCTIONS III 68 FIGURE 135 ...
Page 177: ......