background image

2200293 

_5982

2016 05 02

English

EN

Check, tool connection

 Warning! 

The operator must always check 

that the tool is locked according to the 

description below. In case of doubt, the 

tool must be disconnected and the cause 

investigated. Refer to the Troubleshooting 

section.

•  Check that the locking cylinders have a proper 

grip beneath the tool’s rear shaft. This can be 

confirmed visually by rotating the quick coupler 

so that the rear shaft of the connected tool 

becomes a visible (see figures 14 and 15).

•  As a test, operate a hydraulic function on the 

hydraulic tool. 

Figure 14

Figure 15

Figure 16

Correctly connected

Incorrectly connected

 

IMPORTANT! Checking the quick 

coupler lock 

Even if the indicator shows the locking 

wedge to be in the locked position, 

conduct the following checks to ensure 

it is correctly secured: 

 

-  

Press the tool against the ground, 

(

figure 16

). In this position, extend 

and retract the bucket to check that 

the locking wedge has locked the tool 

correctly.

 

-  

Use the opportunity to rotate the 

quick coupler and, from the operator’s 

position, check the wedge is in its 

locked position.

 

-  

If you are unsure whether or not the 

tool is securely attached, exit the cab 

and check that the locking wedge has 

engaged.

 

-  

Do not operate the machine if the 

quick coupler does not work correctly. 

Contact your dealer immediately if you 

detect faults.

Summary of Contents for Quick Change QC45

Page 1: ...ction of the cylinder unit has space for hydraulic quick connect fittings When the unit s cylinders move the quick coupler locks and the hydraulics are connected simultaneously Connection and disconne...

Page 2: ...1 1 2 3 4 3 4 3 8 3 8 QC60 5 E2 HF E2 HF L 3 4 5 2 1 3 4 1 2 1 2 QC65 L E2 HF E2 HF 3 4 3 4 English EN Quick connect fittings QuickChange quick connect fittings are fitted in the center section of the...

Page 3: ...rea Open the quick coupler lock as described in the Control system operation section Make sure the indicator rod is visible figure 8 Rotate the quick coupler so that the part furthest away becomes vis...

Page 4: ...o the tool s front shaft Lift the tool from the ground so that it hangs freely figure 12 Operate the tiltrotator such that the quick coupler s rear part moves down toward the tool s rear shaft figure...

Page 5: ...Figure 15 Figure 16 Correctly connected Incorrectly connected IMPORTANT Checking the quick coupler lock Even if the indicator shows the locking wedge to be in the locked position conduct the followin...

Page 6: ...Important It is extremely important that the tool be tilted inward otherwise the tool may fall unexpectedly when the coupler is opened Open the quick coupler as per the Control system section Make sur...

Page 7: ...ule see figure 21 In certain cases it may be necessary to adjust the tool Refer also to the grapple module s instructions for use Extra grapple function The extra function enables the use of a grapple...

Page 8: ...otective cover is working as intended Check that there are no leaks The quick coupler and the tool attachment must be kept free of snow and ice in winter As necessary hose or wipe away sand ice and sn...

Page 9: ...grease points Quick coupler grease points are shown below The table lists a description of grease points their number and greasing frequency Pos Description Number of lubrication points Interval 1 Gui...

Page 10: ...use the nose seal is probably damaged and must be replaced Replacing the nose seal quick connect fitting 1 Remove the damaged nose seal 2 Carefully clean around the seat of the fitting 3 Install the...

Page 11: ...e support ring must be inserted first black marking facing up toward the pusher followed by the O ring Then place the pusher on a table or other flat surface and press the seal to the bottom with the...

Page 12: ...he quick connect fitting is now accessible Remove and scrap the locking ring and the steel washer 6 behind it On 1 quick connect fittings fastened with screws remove the screws and their washers and s...

Page 13: ...Pressure relief valve defective Oil leak from the quick connect fittings when the tool is connected The nose seal is missing or damaged Replace the nose seal as described in the section Replacing the...

Page 14: ...H Max 125 Max 150 Max 150 Max 150 Max 250 Max250 Max 250 I 291 5 0 5 341 5 0 5 341 5 0 5 441 1 0 451 5 0 5 551 1 0 591 5 0 5 J 45 f8 60 f8 60 f8 65 f8 70 f8 70 f8 80 f8 K Max 520 Max 600 Max 600 Max...

Page 15: ...2200293 _5982 2016 05 02 English EN Hydraulics diagram quick coupler locking function...