A4
US
US
A4
US
A4
A4
US
9
Redefining Flow Control
hazardous Area Approvals
Refer to the actuator nameplate for it’s specific
approval details.
european - hazardous Area ATeX (94/9/eC) II 2 c T4 gd
ex d IIb T4 gb, ex t IIIC T120 °C db
EN60079-0 and EN60079-1
Ambient Temperature Range:
-20 to +65 °C (-4 to +150 °F)
*Option -40 to +60 °C (-40 to +140 °F)
ex d IIC T4 gb, ex t IIIC T120 °C db
EN60079-0 and EN60079-1
Ambient Temperature:
Range -20 to +65 °C (-4 to +150 °F)
*Option -40 to +60 °C (-40 to +140 °F)
International - hazardous Area IeCex
ex d IIb T4 gb, ex t IIIC T120 °C db
IEC60079-0 and IEC60079-1
Ambient Temperature Range:
-20 to +65 °C (-4 to +150 °F)
*Option -40 to +60 °C (-40 to +140 °F)
ex d IIC T4 gb, ex t IIIC T120 °C db
IEC60079-0 and IEC60079-1
Ambient Temperature Range:
-20 to +65 °C (-4 to +150 °F)
*Option -40 to +60 °C (-40 to +140 °F)
usA - hazardous Area
fM. explosionproof, Class I, div 1, groups C & d, T4
Ambient Temperature Range:
-20 to +65 °C (-4 to +150 °F)
*Option -40 to +60 °C (-40 to +140 °F)
fM. explosionproof, Class I, div 1, groups C & d, T4
Ambient Temperature Range:
-20 to +65 °C (-4 to +150 °F)
*Option -40 to +60 °C (-40 to +140 °F)
fM. dust Ignitionproof, Class II, div 1, groups e, f & g, T4
Ambient Temperature Range:
-20 to +65 °C (-4 to +150 °F)
*Option -40 to +60 °C (-40 wto +140 °F)
Note: A start corresponds to 1% position change on Linear
and Quarter-turn variants and 36º for multi-turn variants.
The CMA is suitable for both indoor and outdoor use up to
an altitude of 5,000 m and is watertight to IP67.