4
x
Operation
19
BA ROTEX GSU - 09/2007
Emission measurement, manual operation, fault clearance function
You can call up 3 functions by using the manual button.
– Functions for emission measurement for the chimney sweep: Tap the manual
button
. First tap: the burner runs at maximum
output, second tap: the burner runs at minimum output.
– Manual operation: press the manual
button for 5 sec
. The ROTEX GSU is controlled according to the set target value (heat
generator temperature). The storage tank charges until the maximum adjustable storage tank temperature is reached. It then
switches over to heating.
– Fault clearance: If the display shows "RESET",
tap
the manual button. If a problem recurs, the root cause must be eliminated.
Display
All system temperatures and operating conditions of the system components can be indicated on the display. In the event of a
fault, the relevant fault signal is issued.
Standard display in normal operation: Current day of the week, current date, current time, heat generator temperature and active
operating mode (marking bar).
4.1.2 Display and modification of parameters
Standard display
Modifying parameters
All parameters for the operation of the heater system can be displayed and set on the boiler control panel. You have no access
to some of the setting areas. They are protected by an access code and can only be called up by authorised technicians.
To modify a parameter, proceed as follows:
• Press the selector keys of the parameters to be set (e.g.
for setting the Automatic timer program).
• Select the parameter value by turning the rotary knob to the left or to the right until the desired value appears in the display.
• Accept the selection by pressing the rotary knob.
This manual will give you an overview of the method of parameter modification in the THETA 23R Control.
A detailed description is given in the operating manual of the control.
You see the current operating parameters in the display during normal
operation:
Day of the week, date, clock time, heat generator temperature
The marking bar identifies the active mode (the example shows the
Automatic timer program II)
Special displays:
– Ice crystal: System anti-freeze active
– Umbrella: Summer switch-off active
Figure 4-2 Standard display