7
x
Technical Data
39
BA ROTEX GSU - 09/2007
Integrated connection group
*
Item number see Fig 7-4
Type
(1)*
GSU 320
GSU 520S
GSU 530S
GSU 535
Parameter
Unit
CVBC Honeywell automatic firing unit
S4965 V 1059 ROTEX
Honeywell gas valve
VK 4115 V2
Burner fan
G1G118/NRG118
G1G126
RG148
Nominal output P
(6)*
kW
3,7-20,0
3,7-20,0
6,5-30,0
8,0-35,0
Rated thermal load Q
(5)*
kW
3,7-21,0
3,7-21,0
6,6-30,9
8,5-36,1
Electrical power consumption (including heating
circulation pump)
(9)*
W
< 114
< 114
< 135
< 148
Device type
(2)*
B
23
, C
13x
, C
33x
, C
43x
, C
53x
, C
63x
, C
83x
Product ID (CE number)
(3)*
CE-0085 BM 0065
NOx class
(4)*
5
Voltage supply
(8)*
230 V~, 50 Hz
Protection type
(10)*
IP 20
Water content
Litres
2,0
3,6
Max. permissable operating pressure:
(12)*
bar
3,0
Max. permissible operating temperature
(13)*
°C
85
Max. boiler efficiency
%
110
Tab. 7-4
Heat generator characteristic data
1
Type
2
Unit type
3
Product ID (CE number)
4
NOx class
5
Rated thermal load
6
Nominal output
7
Operating country
8
Voltage supply
9
Electr. power consumption
10
Protection
11
Net weight
12
Max. permissible operating pressure
13
Max. permissible operating temperature
14
Max. operating pressure
15
D value
16
Manufacturer's number (to be stated in the event
of complaints and queries)
Figure 7-4 Information on type plate on bottom right hand side of storage tank (for information on items see Tab. 7-2 to Tab. 7-4)
GSU
GSU 320/GSU 520S
GSU 530S/GSU 535
GSU
Heating circulation pump
Grundfos UPSO 15-50 CIL 2
Alphaplus 15-60 CIL 2
3-way diverting valve
Voltage
230 V, 50 Hz
230 V, 50 Hz
Maximum power consumption
60 W
75 W
4.3 W
Capacity
2.5 µF
—
Protection type
IP 44
IP 40
Permitted overpressure
3 bar
4 bar
Maximum pumping height
5 m
6.2 m
—
Changeover time
—
—
6 s
Tab. 7-5