4
x
Operation
17
BA ROTEX GSU - 09/2007
4
Operation
4.1
Operating elements on the boiler control panel
4.1.1 Control THETA 23R
Mains switch
Switching the ROTEX GSU on and off When the heating system is on, the mains switch is illuminated in green.
Collective fault signal
During normal operation, the collective fault signal is off. If it lights up, this indicates a malfunction.
Pressure gauge
– Black pointer: Indication of the current water pressure in the heating system.
– Green range: Permitted water pressure range.
– Red pointer: Indication of the permitted minimum pressure.
The black pointer must be in the green range. If it is to the left of the red pointer, the water pressure must be raised by topping
up the system.
The ROTEX GasSolarUnit can be operated with the THETA 23R control or only with the ALPHA 23R control.
The electronic digital controls are to be used for controlling 2 heating circuits (direct heating circuit, mixer
circuit) and a storage tank charging circuit.
A more detailed description is given in the documentation of the "ROTEX Control". It is part of the scope of
supply of the electronic control to be ordered separately.
1
Mains power switch
2
Common fault indicator
3
Not assigned
4
Pressure gauge
5
Control: Central unit THETA 23R
6
Rotary button for selecting and setting functions
and parameters
7
Selection of daytime room nominal temperature
8
Selection of reduced room nominal temperature
9
Selection of nominal temperature of hot water storage tank
10
Selecting the operating mode
11
Setting the automatic timer program
12
System information
13
Manual button for emission measurement, manual operation,
suppression function
14
Display
15
Compartment for quick reference operating manual
16
Retaining bolts for control system
Figure 4-1 Operating elements on the boiler control panel with integrated control THETA 23R
Malfunctioning is generally indicated by an error code on the display.
For troubleshooting information refer to Chapter 6 "Faults and malfunctions".
Summary of Contents for GSU 320
Page 45: ...x Notes 45 BA ROTEX GSU 09 2007...
Page 46: ...Notes 46 BA ROTEX GSU 09 2007...