G) Fasten the “F” labeled terminal end of the FA9190-
7 cable to the positive post of the bottom battery, Fig
37.
H) Fasten the FA9190-5 black cable to the negative
post of the bottom battery, terminal “G”, Fig. 37. The
opposite end is shipped connected to ground.
I) Fasten the “H” labeled terminal end of the
FA9190-10 cable to the negative post of the bottom
battery, terminal “H”, Fig. 37. Fasten the other end of
the FA9190-10 cable to the negative motor terminal,
Fig. 37a.
CAUTION
This step must be completed
last.
CAUTION
When removing batteries always
disconnect black FA9190-10 ground cable first.
J) Re-attach top and bottom cover, Fig. 38.
30. DC Control Cables:
CAUTION
Before making electrical connections,
verify the red disconnect switch on the side panel is
in the
OFF
position.
A) Fasten the “A” labeled terminal end of the FA9190-
8 cable to the positive terminal of the motor, Fig. 37
and Fig. 37a. Fasten the other end of FA9190-8 cable to
the empty motor contact terminal, Fig. 37b.
B) Fasten the “B” labeled terminal end of the FA9190-
12 red cable to the “Battery” side of the disconnect
switch. (Note: FA9190-12 black cable wired to ground
from charger), Fig. 37b.
C) Fasten the “C” labeled terminal end of the FA9190-
6 red cable to the small right terminal contactor, Fig.
37b. (Note: FA9190-6 black cable wired to ground.)
D) Attach battery post connectors to the positive and
negative posts on both the top and bottom batteries,
Fig. 37.
E) Fasten the “D” labeled terminal end of the FA9190-
9 cable to the positive post of the top battery, Fig. 37.
The FA9190-9 cable is shipped connected to discon-
nect.
F) Fasten the “E” labeled terminal end of the FA9190-
7 cable to the negative post of the top battery, Fig 37.
Summary of Contents for SPO16