13
5/16-18NC x 3/8" lg. PHCS
Latch Control
Cover
Air Line
Tubing
Push
Sleeve
Locking Latch Engagement Test:
A)
Raise carriages past the first latch position and then
lower onto latches.
B)
Check that the latches have fully engaged when the
release switch is not depressed.
C)
Raise carriages fully off latches. Now depress release
switch and check that the latches have fully disengaged.
D)
Check for air leaks, make necessary adjustments or
repairs if required.
E)
Install latch covers with 5/16"-18NC x 3/8" lg. PHCS,
Fig. 17.
Note:
Cut provided tubing with sharp blade to length
as required. Tubing must be cut square with no burrs.
To assemble air line tubing into fitting, use firm, manual
pressure to push tubing into fitting until it bottoms, see
below. If removal of the air line tubing from the fitting is
ever required, hold Push Sleeve in (against fitting) and
at the same time, pull out on tubing.
Fig. 17
Overhead
Assembly
To Main Air Supply
APPROACH
Rear View of Lift
Fig. 18
Summary of Contents for SPO16
Page 31: ...31 Notes...