7.
Maintenance
20
7.4 Cleaning
Keep the lift and the lifting zone spotlessly
clean. Never use compressed air, water jets,
solvents, or abrasive cleaning materials to clean
the lift. If possible, avoid build up of dust when
cleaning the lift. Unauthorised staff may not
carry out maintenance work.
Regularly clean the lift.
Only clean the lift when it is not loaded.
Do not use abrasive cleaning materials to clean
the lift parts and covers.
Always use lint-free cloth.
Do not use compressed air or high pressure
cleaners for cleaning.
Always inform the maintenance staff if you
notice any hazards.
To begin cleaning, make sure you first clean the
connections and fittings of oil, grease, and
cleaning materials.
7.5 Check the hydraulic oil level
Check the oil level.
Check the hydraulic oil level of the hydraulic unit
Lower the slider blocks to the bottom position.
Check the hydraulic oil level of the hydraulic
unit. If necessary, top it up with a suitable oil
(see adjacent table ). Use the filling nozzles to
top it up.
Check the hydraulic oil in the tank about every
1000 operating hours (1
0
litres).
Make sure that there is no residue in the tank.
New oil must be filtered.
7.6
Approved hydraulic oils
Important advice
Only use hydraulic oil according to DIN 51524
for hydraulic systems.
Please inform us if you want to use hydraulic oil
from another manufacturer.
ATTENTION
Seals could be destroyed if the
wrong hydraulic oil is used.
Do not use rapeseed-based oil.
The water content in the hydraulic oil may not
exceed 2 %.
Do not mix different types of oil.
Check if there is sufficient oil on the lifting chains
and safety chains. If the coating of oil is too thin,
apply oil with a spray nozzle. Oil and grease
specifications:
Brand
Hydraulic oil Chain oil
Lubricant
TOTAL
AZOLLA 32
CHAINELUB
-
ELF
OLNA DS 32
MOTO
CHAINELUB
-
ESSO
NUTO 7132
-
BP
BARTRAN 32
-
MOLYKOTE
-
BR 2 (1-kg-
box)
7.7 Check the hydraulic
component seals
Only inspect an unloaded lift.
1. Remove the cover plate to gain access to the
hydraulic cylinders
2. Check the seals on all hydraulic components.
3. Switch on the lift.
7.8 Inspect and adjust the
synchronisation cables
Move the lift up to check the tension of the
synchronisation cables.
i
i
i
Summary of Contents for SGL35M
Page 2: ......
Page 39: ...Diagrams spare parts lists 37 Electrical Circuit Diagram single phase...
Page 40: ...Diagrams spare parts lists 38 Electrical Circuit Diagram 3 phase...
Page 42: ...40...
Page 44: ...Diagrams spare parts lists 42 8 9 2 3 5 4 15 1 14 17 7 18 6 16 11 12 10 26 13 11...
Page 45: ...Figure 2 43...
Page 46: ...Diagrams spare parts lists Figure 3 Figure 4 44...
Page 47: ...Figure 5 Figure 7 Figure 6 45 54 57 56 55...
Page 48: ...Diagrams spare parts lists 46 Figure 8...
Page 49: ...Figure 9 47...
Page 50: ...Diagrams spare parts lists 48...