78 • RossTalk Protocol
GPI-8941 User Guide (v9.0)
Get the module type using mixed verbose and terse. Verbose message return is off.
Session Control
These commands and responses allow the session characteristics to be set up and queried.
Message Auto-Response Control
This command controls whether an automatic response is sent after configuration messages. A response to this
configuration command is sent automatically if the session auto-response is on or if Parameter 4 is a status request.
Examples
Turn auto-response off.
Response:
GPI ModuleStatus:Type:GPI-8941
GPI ModuleStatus:Inputs:16
GPI ModuleStatus:Outputs:16
Command:
GPI modulequery: t
Response:
GPI M:T:GPI-8941
Parameter
Description
Terse
Verbose
Command
1
GPI
GPI
GPI command/message class
2
S
SessionConfig
Session setup query command
3
A
AutoResponse
Auto-response control
4
0
off
Turn auto-response off (zero or off)
1
on
Turn auto-response on (one or on)
?
StatusReq
Request current auto-response setting
Response
1
GPI
GPI
GPI command/message class
2
S
SessionStatus
Session setup status message
3
A
AutoResponse
Auto-response control
4
0
off
Auto-response is off
1
on
Auto-response is on
Command:
GPI S:a:0
(terse format)
GPI SessionConfig : AutoResposne : Off
(verbose format)
Response:
none
Summary of Contents for openGear GPI-8941 Series
Page 1: ...GPI 8941 Series User Guide...
Page 6: ......
Page 10: ...iv Contents GPI 8941 Series User Guide v9 0...
Page 16: ...16 Before You Begin GPI 8941 Series User Guide v9 0...
Page 20: ...20 Hardware Overview GPI 8941 Series User Guide v9 0...
Page 30: ...30 GPIO Cabling GPI 8941 Series User Guide v9 0...
Page 32: ...32 Reference Cabling GPI 8941 Series User Guide v9 0...
Page 56: ...56 Software Upgrades GPI 8941 User Guide v9 0...
Page 70: ...70 DashBoard Menus GPI 8941 Series User Guide v9 0...
Page 72: ...72 Technical Specifications GPI 8941 Series User Guide v9 0...
Page 86: ...86 RossTalk Protocol GPI 8941 User Guide v9 0...