Troubleshooting
82 / 89
Warnings
9.2.1
RS14 power generator
Message
Possible cause
Corrective action
Open power genera-
tor compartment.
Compartment is closed.
Open compartment.
Swivel out power
generator!
Do not operate the power
generator in the locker com-
partment.
Open compartment. Swivel out power
generator. Start power generator again.
Switch on power
generator ignition!
Ignition on the power genera-
tor is switched off.
Switch on ignition on the power generator.
Power generator
phase load unequal!
The phase load on the power
generator is unequal.
Connect consumer to equalise the phase
load.
Switch off power
generator main
switch.
The main switch on the power
generator is still active.
Deactivate main switch.
Tank sensor defec-
tive or power genera-
tor inclined
Tank sensor defective.
Inclination of the power gen-
erator too high.
Check/replace tank sensor and switch.
Check the inclination of the power genera-
tor, and correct if necessary.
Fuse has triggered -
reduce load
Fuse has triggered.
Disconnect consumers. Activate fuse. Ob-
serve the maximum permissible load and
connect the consumer.
Emergency stop
pressed
The power generator emer-
gency stop button was
pressed.
Unlock power generator emergency stop
button.
Oil pressure too low
Check oil level and top up if necessary.
Check generator/bat-
tery.
Battery voltage too low. Fault
in the battery charging pro-
cess.
Switch off engine and restart. If the error
persists, inform the service technician.
Unusually high en-
gine temperatures
An engine temperature which
is too high is shown.
Swivel out the power generator. If the
power generator is already swivelled out,
reduce load or stop it. Check engine cool-
ing. If the temperature does not drop,
switch off the generator.