Service and cleaning
77 / 89
Service menu
► For storage without charge retention the battery is to be disconnected.
The leakage current on the electrical components of the power gener-
ator is approx. 0.5 mA.
To prevent the generation of sparks, the earthing cable of the bat-
tery must always be removed first and connected last.
8.7
Service menu
8.7.1
Call up/exit service menu
The service menu can be called up via the
Operating hours
screen
page.
The language of the service menu is set to
English
and cannot be ad-
justed.
Call up service menu
► Actuate
Scroll back screen page
or
Scroll forward screen page
function
switch to display the
operating hours
screen page.
Operating hours
screen page appears on the display.
Operating hours screen page
► Actuate the
Confirm message
function switch for approx. 20 seconds.
The service menu appears in the screen.
The
General
service submenu is automatically selected when
calling up the service menu.
Service menu - General service submenu
Exit service menu
► Actuate the
Confirm message
function switch for approx. 20 seconds.
The service menu is exited.
Changed settings are not automatically saved.
General
Servcie
Log
Stat
L
Language
de
Pressure Unit
Speed Unit
Temperature Unit
Fuel Unit
SAVE DATA CFG
bar
1/min
°C
%
No