Modifications (MODs) / optical data interface
Page 8
RES-430
Version 1
External view of the sub-D socket:
Pin assignment:
5.2.2
DIAG interface for CI-USB-1 (standard as of August 2013)
This data interface has a 6-pole Western socket for connecting the ROPEX communication interface CI-USB-1.
As of August 2013 this data interface is installed on the motherboard of the RES-430 controller as standard. It can
be retrofitted in older controllers (
section 13 "How to order" on page 66).
Only a ROPEX communication interface is allowed to be connected to the DIAG interface. Con-
necting another device (e.g. a telephone cable) could damage the controller and result in malfunc-
tions.
The ROPEX communication interface CI-USB-1 is described in a separate document.
Pin
Signal
1
n.c.
2
TxD (to PC / PLC)
3
RxD (from PC / PLC)
5
GND
4
DTR + DSR
Jumpered internally
6
7
RTS + CTS
Jumpered internally
8
9
n.c.
1
2
3
4
5
6
7
8
9
!