The various cooling modes are shown below:
9.3.5
Setting the cooling value
After the cooling phase has been configured with step 210 in the Configuration menu (
cooling mode" on page 25), you can specify the cooling parameters with step 105 in the Settings menu.
The options available with step 105 in the Settings menu vary according to the selection made with
step 210 in the Configuration menu. All settings entered with menu step 105 are overwritten if
step 210 is changed subsequently.
The possible settings are as follows:
1.
"Cooling temp. in °C" (if setting with menu step 210 = "Absolute")
The cooling phase of the internal timeout ends when the ACTUAL temperature of the heatsealing band falls
below the SET temperature.
The minimum settable temperature is 50°C. This is also the factory setting.
The maximum value of the setting range is limited either by the maximum value specified with
step 206 in the Configuration menu or by the temperature range set with step 205.
2.
"Cooling temp. in %" (if setting with menu step 210 = "Relative")
The cooling phase of the internal timeout ends when the ACTUAL temperature falls to the specified percentage
ACTUAL
temp.
START
signal
ON
T
t
t
0
0
Cooling mode
T
t
0
T
t
0
T
t
0
Absolute
Relative
Time
T
2
X%
t
3
t
3
t
3
t
3
= Cooling phase in
t
3
= Cooling phase as
% of set point
t
3
= Cooling phase in s
!
!