Startup and operation
Version 1
RES-430
Page 23
It is only possible to start a heating process with the "HAND" key (assuming step 213 has not been
locked in the Configuration menu and the display is in the home position) on the controller. The
timeout of the internal time control cannot be started with this key.
The timeout of the internal time control (timer function) can only be interrupted by switching off the
controller or by deactivating the "START" signal.
If the display is in the home position, the individual timeouts can be monitored there.
The remaining heatsealing time is indicated on the display in the form of a countdown at the end of the heating
phase. A direction arrow indicates the active process.
The active cooling phase is subsequently marked with the direction arrow at the end of the heating phase.
The direction arrow disappears again at the end of the cooling phase (i.e. at the end of the internal timeout).
!
ACTUAL
temp.
START
signal
ON
T
t
t
0
0
Relay K1
closed
t
0
t
1
t
2
t
3
t
1
= Starting delay
t
2
= Heating phase
t
3
= Cooling phase
!