Page 21
System configuration
© 2017 Ropam Elektronik
remaining module functions are available, the events generated on the inputs and outputs are written
to the module memory.
Sending SMS active:
SMS of system event notification enabled. Unchecking this option will cause the
module to miss sending SMS messages.
Active ringing:
The system event notification function is activated as a ringing tone for the user. In
addition to the notification in the form of rings, they are also sent messages from the voice synthesizer:
VSR-1, VSR-2 module AMR-1. When the function is inactive - no possibility to send notifications CLIP
and voice module BasicGSM 2.
When there is a need to use the module as a stand-alone BasicGSM 2 control unit - then turn off the
options for sending SMS and dzwonienia- module will not turn on GSM modem and thus the system
will not appear on the failure of GSM / calling / sending SMS.
SMS CENTER
The number of the SMS center, select on the operator tab from the list (the number will be displayed
automatically) or edit the field. The number should be entered in international format.
COMMENTS:
The module has the option to automatically retrieve the SMS center number from the SIM card
inserted into the nano SIMCARD connector.
If there is no possibility of automatic identification of the SMS center by module - select
operator manually and save to the module.SMS CENTER must be the SMS center number of
the GSM network operator of the SIM card in the module phone! No number or incorrect
number will block SMS sending!
APN SETTINGS:
APN settings:
Access point settings (internet via GPRS). Required to control the module from the
RopamBasic application, GPRS monitoring, sending email notifications from the module.