Page 54
System configuration
© 2017 Ropam Elektronik
INSERT PIN CODE
Pressing ENTER PIN CODE will be sent to the module telephone command to enter the PIN code,
which is currently displayed in the SIM CARD PIN. This option allows you to test the SIM card of
different operators without having to change and save the configuration. The configuration stored in
BasicGSM 2 must have marked PIN CODE IS NOT REQUIRED to block automatic PIN code entry by
module procedure.
COMMENTS:
- any changes to the SIM card, jumper settings, module connections and interfaces should be
made after disconnecting module power and maintaining all available antistatic protection.
SET TIME AND DATE
Pressing the SET TIME AND DATE box saves the time and date from the PC to the module. The
correct time and date is required to send a transmission test according to the clock and correct record
of events in event memory. Time setting is also possible via SMS configuration TIME, SMS format:
xxxx TIME year, month, day hour, minute where xxxx is the ACCESS CODE.
SMS CONTROL EMULATOR:
A feature that allows local control of the module from BasicGSM Manager. The emulator allows you to
keep track of the module's response for online commands. No need to generate SMS messages from
users phone.
RESTART MODULE:
Restart the modem feature, you should change the settings module, reconfigure especially APN, e-
mail, problems in the operation of the GSM network, problems with logging on to the BTS to test the
proper operation of the operator SIM card in the module.