Section 5.4: Smart Controller/Smart Switch Error Indicators
The error indicator LEDs to the left of the Open and Close buttons on the Smart Controller and Smart Switch are used to
troubleshoot door issues, display the door's operational status, and warn personnel of door movement.
1. If an LED is solid, the corresponding sensor has encountered an error.
2. If all eight LEDs fade together, the door is in a timed open cycle and will eventually begin a close cycle.
3. If all eight LEDs flash together, the door is either moving or about to move.
Code
Condition
Problem Area
PS
Primary Safety
Safety Beam (Emitter and Receiver Near Bottoms of Tracks)
AS
Auxiliary Safety
Auxiliary Safety Sensor (Motion Sensor in Head Unit)
LE
Leading Edge
Leading Edge Switch (Mechanical Switch in Head Unit)
HM
Home Sensor
Home Sensor (Fixed-field Sensor in Head Unit)
FE
Feedback Error
Encoder (Error with Encoder Counting or Door Not Operating)
OP
Open Switch
Open Activation
CL
Close Switch
Close Activation
ST
Stop Switch
Stop Switch (if Present)