4801-5164J
20 October 2021
28
RS-500 5K Walk-In Cooler Door Installation and Operation Manual
Section 3.7: Smart Controller User Interface
The user interface is used to view information and settings on the Smart Controller. It consists of the Display Indicator; four LEDs
labeled with the corresponding readings; the Up and Down directional arrows; and the Mode button. Only one reading is shown
on the Display Indicator at a time. Pressing the Mode button toggles the Display Indicator to the next reading and turns the
corresponding LED solid green.
The five readings shown on the Display Indicator are as follows:
1. Actual Position - This is the position of the door as measured in counts (see Section 3.6). The minimum reading indicates the
door is fully open, whereas the maximum reading indicates the door is fully closed.
2. Open Speed - This is the speed at which the door is programmed to open, represented as a percentage of the drive motor's
full speed. This setting can be changed from a minimum of 20% to a maximum of 100% (see Section 3.8.2).
3. Close Speed - This is the speed at which the door is programmed to close, represented as a percentage of the drive motor's
full speed. This setting can be changed from a minimum of 20% to a maximum of 50% (see Section 3.8.2).
4. Total Cycles - This is the total number of times the door has been opened and closed, represented in increments of 100. For
example, a reading of 20 means the door has been operated between 2,000 and 2,099 times.
5. Service Cycles - This is the number of times the door has been opened and closed since the last service reset, represented in
increments of 100. For example, a reading of 5 means the door has been operated between 500 and 599 times since the last
service reset. See Section 3.8.1 for details on resetting this reading and on setting service reminders.
NOTICE:
Total Cycles and Service Cycles are represented by the same LED. After selecting Total Cycles, press the Mode button once
to display Service Cycles.
Section 3.7.1: Overview