FEDL22660-01
ML22660
Command flow when reading data
Start condition
Slave aW(0)
RDSTAT Command
Stop condition
Start condition
Slave a R(1)
Read data (ex. Status read)
Stop condition
SCL
SDA
S
A
A
Slave Address
RDSTAT Command
A6 A5 A4 A3 A2 A1 A0
A
W
D7 D6 D5 D4 D3 D2 D1
A
D0
P
CBUSYB
SCL
SDA
A6 A5 A4 A3 A2 A1 A0
A
R
D7 D6 D5 D4 D3 D2 D1
A
D0
A
A
Slave Address
Read Data*
1
S
P
CBUSYB
- Timing chart when reading data.
*1
When the two-time input mode, the error state reading is 2 bytes
The data read flow is used when data is read by RDSTAT/RDERR/RDVER commands. The data to be read is updated by
inputting RDSTAT/RDERR/RDVER command. Be sure to enter the RDSTAT/RDERR/RDVER command before reading
the internal status.
The slave address can be set as follows using the SAD2 to SAD0 pins.
SAD2
SAD1
SAD0
Lower 4 bits
Slave address
0
0
0
0101
000_0101
0
0
1
0101
001_0101
0
1
0
0101
010_0101
0
1
1
0101
011_0101
1
0
0
0101
100_0101
1
0
1
0101
101_0101
1
1
0
0101
110_0101
1
1
1
0101
111_0101