FEDL22660-01
ML22660
SAFE command
・
Command
1
1
0
1
0
0
0
0
1st byte
OSCEN
RSTEN
WDTEN
ROMEN
SPDEN
TSDEN
DCDEN
WCMEN
2nd byte
The SAFE command is used to set the operation of the misoperation detection function and the failure detection function.
The initial value is the operation stop state ("0"). When this bit is set to "1", operation starts.
Error setting
Description
WCMEN
Set the command error detection.
DCDEN
Set the disconnection detection of the speakers connected to the SPP and SPM pins.
TSDEN
Set the LSI temperature error detection.
SPDEN
Set the detection of short circuit between the SPP pin and the SPM pin.
ROMEN
Set error detection of flash memory.
WDTEN
*1
Operate the watchdog timer and set overflow detection.
RSTEN
*1
Operate the RST counter and set overflow detection, when any error is detected.
OSCEN
Set stop detection of clock input from a crystal resonator or ceramic resonator.
*1 Do not set WDTEN and RSTEN to "1" at the same time. If these bits are set to "1" at the same time, only the RSTEN bit
is set to "1".
For details on misoperation detection and failure detection, refer to the "Misoperation detection and failure detection
functions" in the function description.
For the timing of the SAFE command, refer to the "SAFE command timing" in the timing chart.
85/116
Summary of Contents for LAPIS Semiconductor ML22660