5 | Assembly of the Centric Clamp
26 / 44
KZS-H_KZS-HG
Remove seals of the connections
Direct connection
Connection via pipelines
a)
Insert the O-rings into the sealing
seats of the pressure connections
(assembly surface).
b)
Remove the threaded pins from
the corresponding connections on
the underside of the centric clamp
(Open, Close and , if fitted, Seal-
ing Air and 2x lubrication).
c)
Leave all other connections
sealed.
a)
Remove the seals of the connec-
tions (Open, Close and, if fitted,
Sealing Air) on the fronts of the
body and connect pressure lines.
b)
Leave all other connections
sealed.
Positioning the centric clamp
With clamping sleeves
With cylindrical pins
a)
Insert clamping sleeves into the
corresponding locating holes on
the machine table as far as they
will go.
b)
Mount in such a way that the pro-
truding part of the clamping
sleeves engages with the locating
holes on the body.
a)
Insert cylindrical pins into the cor-
responding locating holes on the
machine table as far as they will
go.
b)
Mount in such a way that the pro-
truding part of the cylindrical pins
engages with the locating holes
on the body.
5.4
Mounting the Inductive Proximity Switches
NOTICE
Ingress of dirt and swarf.
Damage to the centric clamp.
Ø
Never operate the
centric clamp
without the proximity switch
screwed in.
On assembly, do not excessively twist the connection cables and pos-
sibly always turn them as well.