5 | Assembly of the Centric Clamp
30 / 44
KZS-H_KZS-HG
Function with internal clamping
S1: 0
S2: 0
S1: 0
S2: 1
S1: 1
S2: 0
S1
S2
Hubendlage geöffnet
Spannstellung
Hubendlage geschlossen
Stroke end position closed
Clamping position
Stroke end position open
The switching diagram shows the recommended setting of the proximity
switches “S1” and “S2” on query of the “end-of-stroke position closed” and
“reached clamping position”.
The proximity switches can be moved on the holding plate in order to alter the
query to “End-of-stroke position open” and “Overrunning the clamping posi-
tion”.
Switching diagram proximity switch
Proximity switch
S1 (end position)
S2 (clamping position)
Signal output
0
1
0
1
Jaw end position down,
centric clamp closed
X
X
Clamping position
X
X
Jaw end position up,
centric clamp open
X
X
The bar serves as a position sensor for the proximity switches. When the
proximity switch is activated (1 is displayed), the status LED on the proximity
switch is lit.