5 | Assembly of the Centric Clamp
28 / 44
KZS-H_KZS-HG
Setting the proximity switch
S1
S2
1.
Set the switching point of the left-hand proximity switch (S1) so that the
corresponding switching signal is active when the stroke end position is
open or closed.
2.
Set the switching point of the right-hand proximity switch (S2) so that a
switching signal is active in the area of the clamping position.
3.
Fix the proximity switches with the lock nut. Only slightly tighten the lock
nut.
4.
Clamp and open the centric clamp to test the reaction of the proximity
switches.
Ø
The status LED on the proximity switch is lit when a signal (switching
signal “1”) is issued (see
table “Switching diagram proximity
switch”)
.
ü
Proximity switch mounted and set.
Summary of Contents for KZS-H