Preparing for Use
R&S
®
TSME
15
User Manual 1514.6542.02 ─ 10
2.2
Connecting the R&S
TSME
This section describes how to connect the R&S
TSME to the other devices in the mea-
surement setup (see also
Chapter 1.2, "Measurement Setup"
Connecting the DC Power Supply
...........................................................................15
Setting Up the LAN Connection to the Host PC
......................................................16
..................................................................................21
............................................................................... 22
TSMEs to one Host PC (LTE MIMO Setups, Parallel
2.2.1
Connecting the DC Power Supply
The DC power supply connector is on the rear panel of the unit. Voltages from 10
V to
27
V are supported. There is no need to set the used voltage manually.
Possible power cable connections
The R&S
TSME can work with the following DC power supplies:
●
Cigarette lighter power supply (for example in a vehicle) using the supplied DC
power cable
●
Optional AC power supply and power cable R&S
●
Proprietary power supply with an adapted power cable
Using the supplied cigarette lighter power supply cable
► To use the power supply from a cigarette lighter, connect the supplied power cable
from the R&S
TSME to the cigarette lighter.
Connecting a proprietary power supply
► To use a proprietary DC supply with the R&S
TSME power cable, demount the cig-
arette lighter adapter from the supplied power cable and connect the open ends of
the cable to the proprietary power supply. Be sure to respect the correct polarity
(see
).
Connecting the R&S
TSME