PR821-CH User Manual.doc
2018-04-05
20/29
AUX
1
- Function cards:
[FP12]:Set AUX1
[FP14]:Toggle AUX1
- Inputs/Function keys:
[71]:Set AUX1
[73]:Toggle AUX1
- Remotely from PR Master software
- Function cards:
[FP13]:Clear AUX1
[FP14]:Toggle AUX1
- Inputs/Function keys:
[72]:Clear AUX1
[73]:Toggle AUX1
- When flag time (timer) elapses
- Remotely from PR Master software
AUX1 is general purpose flag. When the flag is activated then
output with the function
[66]:AUX1
is activated and event
[048]:AUX1 is on
is generated.
AUX
2
- Function cards:
[FP20]:Set AUX2
[FP22]:Toggle AUX2
- Inputs/Function keys:
[74]:Set AUX2
[76]:Toggle AUX2
- Remotely from PR Master software
- Function cards:
[FP21]:Clear AUX2
[FP22]:Toggle AUX2
- Inputs/Function keys:
[75]:Clear AUX2
[76]:Toggle AUX2
- When flag time (timer) elapses
- Remotely from PR Master software
AUX2 is general purpose flag. When the flag is activated then
output with the function
[67]:AUX2
is activated and event
[050]:AUX2 is on
is generated.
IN
TR
U
D
ER
- Input:
[08]:TAMPER
- Inputs when the option
Enable anti-
burglary functions
is selected and
ARMED flag is activated:
[01]:Door contact
[09]:INTRUDER
[16]:Window contact
[15]:INTRUDER – delayed
- Controller disarming
- When flag time (timer) elapses
- Remotely from PR Master software when
alarm(s) are cleared
INTRUDER flag is used for anti-burglary functions of PR821-CH
controller. When the flag is activated then output with the function
[68]:INTRUDER
is activated and event
[052]:INTRUDER is
ON
is generated. Full description of intruder alarm functionalities is
given in section 6.7 Intruder alarm system.
D
U
R
ES
S
- When PIN differing by +/-1 from any
correct PIN is entered on reader keypad
- When flag time (timer) elapses
DURESS flag has no particular application in hotel automation
system especially when readers with keypads and PINs are not
applied.