PR821-CH User Manual.doc
2018-04-05
21/29
TR
OUBL
E
- Inputs:
[05]:AC lost
[06]:Low battery
- Lost communication with XM-2 expander
- Controller disarming
- When flag time (timer) elapses
TROUBLE flag is used for signalling power supply problems.
EN
TR
Y DE
LAY
- Input:
[15]:INTRUDER–delayed
- Controller disarming
- When flag time (timer) elapses
ENTRY DELAY flag is used in anti-burglary functions of PR821-CH
controller. If the controller is not disarmed by inserting authorized
card into holder before ENTRY DELAY timer elapses then
INTRUDER flag is activated. As long as ENTRY DELAY flag is
activated anti-burglary functions are disabled and signals on inputs
[01]:Door
contact
,
[15]:INTRUDER-delayed
and
[16]:Window contact
are ignored. ENTRY DELAY flag is used
only if the option
Enable anti-burglary functions
in
controller properties in
Options
tab is selected. When the flag is
activated then output with the function
[71]:ENTRY DELAY
is
activated.
EXIT
D
EL
AY
- When card is removed from holder and
controller becomes armed
- Controller disarming
- When flag time (timer) elapses
EXIT DELAY flag is used in anti-burglary functions of PR821-CH
controller. As long as EXIT DELAY flag is activated anti-burglary
functions are disabled and signals on inputs
[01]:Door contact
,
[15]:INTRUDER-delayed
and
[16]:Window contact
are
ignored. EXIT DELAY flag is used only if the option
Enable anti-
burglary functions
in controller properties in
Options
tab is
selected. When the flag is activated then output with the function
[72]:EXIT DELAY
is activated.
POW
ER
SU
PP
LY
- When CARD IN HOLDER flag is activated
by authorized user card in holder
- Remotely from PR Master software
- When authorized user card is removed
from holder plus time specified by POWER
SUPPLY – SWITCH OFF DELAY timer
POWER SUPPLY flag is used for 230VAC power supply control in
hotel room. If the flag is switched on remotely from PR Master
software then it will not switch off automatically and it requires
remote deactivation from the software. When the flag is activated
then output with the function
[48]:POWER SUPPLY
is
activated. Full description of the feature is given is section 6.5
Power supply (230VAC) control