Fig. 9 PR821-CH flags
Table 5. System flags
Flag
Flag activation
Flag deactivation
Flag activation effect
LIG
HT
- Function cards:
[FP15]:Set LIGTH
[FP17]:Toggle LIGHT
- Inputs/Function keys:
[68]:Set LIGHT
[70]:Toggle LIGHT
- Remotely from PR Master software
- Function cards:
[FP16]:Clear LIGHT
[FP17]:Toggle LIGTH
- Inputs/Function keys:
[69]:Clear LIGHT
[70]:Toggle LIGHT
- When flag time (timer) elapses
- Remotely from PR Master software
LIGTH flag is used to control lighting in hotel room. When the flag
is activated then output with the function
[64]:LIGHT
is
activated and event
[046]:LIGHT is on
is generated.
TAMP
ER
- Input:
[08]:TAMPER
- Controller disarming
- When flag time (timer) elapses
- Remotely from PR Master software when
alarm(s) are cleared
TAMPER flag is used for alarming unauthorized controller
disassembly or sabotage. When the flag is activated then events
[052]:INTRUDER is on
and
[540]:Tamper Alarm ON
are generated and INTRUDER flag is activated.