1.1 This manual
This manual contains minimum information that is necessary to properly install device, perform
initial test and configure for hotel applications. Following documents which are available at
www.roger.pl
supplement this manual:
Functional description of PRxx1 controllers,
PR Master User Manual
2.
D
ESCRIPTION AND SPECIFICATION
PR821-CH is single room/door controller used in RACS 4 access control system and it additionally
offers hotel automation and intruder alarm functionalities. PR821-CH is equipped with card holder
and built-in two system EM125kHz/MIFARE® reader. Peripheral devices communicating in RACS
CLK/DTA format such as HRT82MF hall reader, function key panel HRT82FK and XM-2 I/O expander
can be connected to the controller.
Controllers can be configured with PR Master software installed on computer and they can be
connected to computer by means of communication interface e.g. UT-2USB, UT-4DR, RUD-1 or by
means of CPR32-NET network controller.
Note: PR821-CH controllers require PR Master 4.5.14 or newer.
Table 1. Specification
Supply voltage
Nominal 12VDC, min./max. range 10-15VDC
Proximity cards
EM 125 kHz (UNIQUE) in accordance with EM4100/4102 and
13.56 MHz in accordance with ISO/IEC 14443A and MIFARE
Average
current
consumption
100mA
Tamper
Isolated contact, NC type, 24V/50 mA rated
Inputs
Three (IN1..IN3) NO/NC inputs, electrically biased to +12V via 15kΩ
resistor, triggering level approx. 3.5V
Relay output
One (REL1) relay output with single NO/NC contact, 30V/1.5A
Transistor outputs
Two (IO1,IO2) open collector outputs, 15VDC/1A
Distances
Between controller and communication interface (RS485): max. 1200m
Between reader and controller: max. 150 m
Between controller and I/O expander: max. 150 m
Environmental class
(according to EN
50131-1)
Class II, indoor general conditions, temperature: -10°C- +50°C, relative
humidity: 10 to 95% (no condensation)
IP code
IP41
Dimensions HxWxD
85 x 85 x 27 mm
Weight
approx. 120g
Certificates
CE