Figure 66 - Pipe Flange Detail
Table 5 - Customer Cooling Requirements for Liquid-to-Liquid Heat Exchangers
Process Water Inlet
Drive Coolant Outlet
1.25 in. or 2.0 in. NPTF
Female Pipe Threads
Process Water Outlet
Drive Coolant Inlet
Drive
Min. Flow Rate
Max. Pressure
(psig)
Pressure Drop
(kPa)
Temperature (°C)
Rectifier
Voltage
Amps
US Gpm
(1)
L/m
(2)
Min.
Max.
18 Pulse
4160
375
19.5
72
435
7
> 0
<32
430
21.5
80
435
8
> 0
<32
495
26.5
100
435
13
> 0
<32
575
29.0
109
435
15
> 0
<32
657
37.5
142
435
25
> 0
<32
6600
375
33.0
125
435
18
> 0
<32
430
44.5
167
435
34
> 0
<32
495
48.5
184
435
40
> 0
<32
575
54.5
206
435
43
> 0
<32
657
62.6
237
435
49
> 0
<32
AFE
4160
375
19.5
74
435
7
> 0
<32
430
24.0
90
435
10
> 0
<32
495
26.5
100
435
13
> 0
<32
575
33.0
125
435
19
> 0
<32
6600
375
37.0
139
435
24
> 0
<32
430
44.5
167
435
34
> 0
<32
495
48.5
184
435
40
> 0
<32
575
54.5
206
435
43
> 0
<32
(1) US Gpm = Gallons per minute (U.S.)
(2) L/m = Liters per minute