Rockwell Automation Publication 750-TG101A-EN-P - June 2022
97
Chapter 5 Frame 6 Renewal Kits Installation
Install the Backplane Circuit Board
Install the backplane circuit board in the reverse order of removal.
•
Do not remove the protective covers from the connectors on the new
backplane circuit boards unless a connection must be made during
installation.
Heatsink Fan Replacement
Replacement kit catalog numbers: SK-RT-HSFAN1-F6, SK-RT-HSFAN1-F6-XT.
These kits can be used for IP00, NEMA/UL Open Type and IP21, NEMA/UL
Type 1 enclosures.
Replacement kit catalog number: SK-RT-HSFAN2-F6- XT. This kit can be used
for flange, NEMA/UL Type 4X/12 back and IP54, NEMA/UL Type 12 enclosures.
Remove the Heatsink Fan
Follow these steps to remove the heatsink fan.
1. Review the
.
2. Turn off and lock-out incoming power. See
.
3. For IP54, NEMA/UL Type 12 enclosures, open the enclosure door and
remove the protective guard. See
Remove the Protective Guard (IP54,
NEMA/UL Type 12 Enclosure) on page 84
.
IMPORTANT
Do not remove protective covers unless used at the time of installation. For
the product to meet the corrosive atmosphere rating, protective covers
must remain installed in unused connectors during storage and operation.
See
Protective Covers on Kits with XT on page 16
for details.