Chapter 5 Frame 6 Renewal Kits Installation
20. Remove the M4 x 8 mm slotted-Torx screw and metal tab from the M4
standoff on the power interface circuit board.
21. Remove the M4 standoff from the power interface circuit board.
22. Remove the five M4 x 14 mm slotted-Torx screws from the power
interface circuit board.
23. Remove the five M4 x 8 mm Torx screws that secure the power interface
circuit board to the standoffs on the chassis and remove the board.
23
M4 x 8 mm
T20 or F - 6.4 mm (0.25 in.)
2.6 N
•
m (23.0 lb
•
in)
22
M4 x 14 mm
T20 or F - 6.4 mm (0.25 in.)
2.6 N
•
m (23.0 lb
•
in)
20
M4 x 8 mm
T20 or F - 6.4 mm (0.25 in.)
2.6 N
•
m (23.0 lb
•
in)
21
M4 x 8 mm
T20 or F - 6.4 mm (0.25 in.)
2.6 N
•
m (23.0 lb
•
in)
20
22
21
23
22
23
23
23