Rockwell Automation Publication 750-TG101A-EN-P - June 2022
41
Chapter 4 Frames 1…5 Renewal Kits Installation
Install the IP54, NEMA/UL Type 12 Cover, Frames 2…5
Follow these steps to install the cover.
1. If present, insert any unused PE jumper screws into the PE retainer on
the inside of the new cover.
2. Install the IP54, NEMA/UL Type 12 cover in the reverse order of removal.
Chassis Replacement,
Frame 1
Replacement kit catalog numbers: SK-RT-CHSS1-F1, SK-RT-CHSS1-F1-XT
These kits can be used for IP20, NEMA/UL Open Type, IP20, NEMA/UL Type 1,
and Flange, NEMA/UL Type 4X/12 back enclosures.
Remove the Chassis, Frame 1
Follow these steps to remove the chassis.
1. Review the
.
2. Turn off and lock-out incoming power. See Remove Power from the
Remove Power from the System on page 12
.
3. Remove the power terminal cover. See
.
4. For IP20, NEMA/UL Type 1 enclosures only, insert a screwdriver under
the drip hood, press outward to disengage each clip, and lift the cover off
the chassis. Retain the drip hood for reuse.