Configure POINT I/O Modules in RSLogix 5000 Software
Enter Values on the Configuration dialog
Enter values on this dialog based on the type of module with:
•
overload diagnostic status.
•
overload and open load diagnostic status.
To complete the entries on this dialog proceed as follows.
1.
From the General dialog, select Configuration.
You see the Configuration dialog, which displays configuration data for
each channel in individual rows in a table. The number of output
channels varies based on the type of module as in the following
examples:
•
The 1734-OB2E module has two output channels (0…1).
•
The 1734-OB4E module has four output channels (0…3).
•
The 1734-OB8E module has eight output channels (0…7).
See the figure for a Configuration dialog for a 4-point output module. The
2-point and 8-point output modules are identical except for the number of
point you can configure.