Use isopropyl alcohol and a rag to clean any Reverb fluid from the
seatpost.
9
Pull up on the remote syringe plunger and slowly depress the
remote actuator. Press in on the remote syringe plunger until the
remote lever fully extends. Repeat this process a few times until no
more bubbles are pulled from the system.
10
Depress the remote syringe plunger and make sure the remote
actuator is fully extended. Remove the syringe and use a
T10 TORx
®
to reinstall the bleed screw and tighten to 1.1-2.2 N•m
(10-20 in-lb).
Use isopropyl alcohol and a rag to clean any Reverb fluid
from the remote.
11
Depress the remote actuator five times. Release it to allow the
actuator to return to its extended position.
Pull back on the actuator. If it doesn't move, you have successfully
bled the remote and are finished servicing your Reverb Stealth.
If a gap is present, repeat remote bleed steps 5-11, pages 28-29.
T10 1.1-2.2 N•m (10-20 in-lb)
Do not exceed 6.7 N•m (59.3 in-lb)
29
REMOTE AND HOSE BLEED