A-6
ROBOVENT • SPIRE SERIES OWNER’S MANUAL
APPENDIX A
Wiring Diagram
VFD Parameters
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
A
A
B
B
C
C
D
D
DRAWN
CHECKED
QA
MFG
APPROVED
DWG
NO
TITLE
SIZE
SCALE
REV
TOLERANCE
:
.XX
±
.0625
.XXX
±
.03125
ANGLE
±
1°
UNLESS
OTHERWISE
SPECIFIED
ALL
DIMENSIONS
IN
INCHES(mm)
3rd
Angle
Projection
MATERIAL
SPEC
ASTM
A1011
CS
TYPE
B
HOT
ROLLED
SHEETS
<=
.1943
MATERIAL
TYPE
THICKNESS
ASTM
A1018
CS
TYPE
B
HOT
ROLLED
SHEETS
>.1943
POWDER
COAT
SPEC
ALL
POWDER
COATED
COMPONENTS
MUST
MEET
AAMA
2603
STANDARDS
ANY
REPRODUCTION
IN
PART
OR
AS
A
WHOLE
WITHOUT
THE
WRITTEN
PERMISSION
OF
ROBOVENT©
IS
STRICTLY
PROHIBITED
PROPRIETARY
AND
CONFIDENTIAL
\}
REVISION
HISTORY
REV
DESCRIPTION
DATE
APPROVED
KGHOLSTON
10/16/2019
D
0
VFD
PARAMETERS
SHT5
OF
5
Configuration:
Characteristics
:
Max
Transient
Current
41.6
A
Nominal
Current
27.7
A
Supply
Voltage
400
V
Nominal
Power
11
KW
Structure
Device
ATV320D11N4B
Serial
Number
XX
X9
26
112
347
Version
V2.9IEXX
Vendor
Name
Schneider
Electric
Control
Board
Serial
Number
XX
X9
22
064
060
Version
V1.5IE13
Vendor
Name
Power
Board
Serial
Number
XX
X9
22
064
060
Version
V1.5IE13
Vendor
Name
Option
Board
Serial
Number
Version
Vendor
Name
Motor
Configuration
Software
Release
1.2.6.0
Safety
State
STD
Parameter
List:
Modified
Parameters
Code
Long
Label
Conf0
Default
Value
Min
Value
Max
Value
Logical
address
BFR
Std.
motor
frequency
60Hz
NEMA
50Hz
IEC
3015
NCR
Nominal
motor
current
16.6
A
21.3
A
6.9
A
41.5
A
9603
NSP
Nominal
motor
speed
3525
rpm
1766
rpm
0
rpm
65535
rpm
9604
TFR
Max.
output
frequency
60
Hz
72
Hz
10
Hz
599
Hz
3103
ITH
Motor
thermal
current
16.6
A
21.3
A
5.5
A
41.5
A
9622
LSP
Low
speed
15
Hz
0
Hz
0
Hz
60
Hz
3105
RSA
Cust
stator
resistance
321
mOhm
0
mOhm
0
mOhm
65535
mOhm
9642
LFA
Cust
leakage
inductance
4.68
mH
0
mH
0
mH
655.35
mH
9662
IDA
Cust
adjust
magn.
current
7.7
A
0
A
0
A
6553.5
A
9652
TRA
Custom
rotor
t constant
370
ms
0
ms
0
ms
65535
ms
9667
RSAS
Cust.
stator
resist.
(sync)
321
mOhm
0
mOhm
0
mOhm
65535
mOhm
9682
LDS
Sync
motor
d
inductance
4.68
mH
0
mH
0
mH
655.35
mH
9674
LQS
Sync
motor
q
inductance
4.68
mH
0
mH
0
mH
655.35
mH
9675
PHS
Sync.
EMF
constant
100.8
mV/rpm
0
mV/rpm
0
mV/rpm
6553.5
mV/rpm
9673
AI1A
AI1
assignment
No
Ref.1
channel
4821
AI2T
Configuration
of
AI2
Voltage
Voltage
+/-
4403
CRL3
AI3
minimum
value
4
mA
0
mA
0
mA
20
mA
4434
AI3F
AI3
filter
1
s
0
s
0
s
10
s
4454
FR1
Configuration
reference
1
Modbus
AI1
8413
RIN
Reverse
direction
inhibit.
Yes
No
3108
CHCF
Channel
mode
config.
I/O
profile
Not
separ.
8401
CD1
Control
channel
1
config.
Modbus
Terminals
8423
FN4
F4
key
assignment
FNTK
NO
13504
BNV
Program
format
version
1
0
0
65535
14990
CTV
Catalogue
version
1
0
0
65535
14991
ADD
Drive
modbus
address
2
OFF
OFF
247
6001
BDRU
Data
rate
used
Not
config.
Automatic
6660
CIO2
Configured
Assembly
20/70
21/71
6668
RSF
Fault
reset
input
assign.
CD07
NO
7124
Summary of Contents for Spire MLS-01-5500-10
Page 2: ......
Page 6: ......
Page 7: ...ROBOVENT SPIRE SERIES OWNER S MANUAL 7 SECTION 100 Important Safety Instructions ...
Page 9: ...SECTION 200 Glossary of Terms ...
Page 13: ...SECTION 300 Features of the Spire Series Collector ...
Page 18: ...18 ROBOVENT SPIRE SERIES OWNER S MANUAL ...
Page 19: ...SECTION 400 Receiving Inspection ...
Page 21: ...SECTION 500 Installation ...
Page 26: ...26 ROBOVENT SPIRE SERIES OWNER S MANUAL ...
Page 27: ...SECTION 600 Start up Commissioning ...
Page 31: ...SECTION 700 System Balancing ...
Page 39: ...SECTION 900 Maintenance ...
Page 52: ...52 ROBOVENT SPIRE SERIES OWNER S MANUAL ...
Page 53: ...ROBOVENT SPIRE SERIES OWNER S MANUAL 53 SECTION 1000 Troubleshooting ...
Page 58: ...58 ROBOVENT SPIRE SERIES OWNER S MANUAL ...
Page 59: ...APPENDIX A General Wiring Diagrams ...
Page 65: ...APPENDIX B Parts List ...
Page 66: ...B 2 ROBOVENT SPIRE SERIES OWNER S MANUAL APPENDIX B Parts List C D E F G M L K J I H A B ...