ENG
MAINTENANCE INFORMATION
102
7.2. PERIODICAL MAINTENANCE INTERVALS
Important
Keep the machine in maximum efficiency conditions and perform all the scheduled maintenance
operations provided for by the Manufacturer.
Proper maintenance will provide the best performance, a longer life span and constant compliance with
safety requirements.
Maintenance interval table
Frequency
Component
Type of intervention
Intervention mode
Reference
Every 200 hours
Machine
General check
Clean with a cloth or
air jet.
-
Every 2000 hours
Rotary ring belt
General check
Check for wear and
replace, if necessary.
Contact the assistance
service.
-
Tension adjustment
See “Rotary ring
belt -
Adjustment”.
Conveyors
General check
Check belt for wear
and replace, if
necessary. Contact the
assistance service.
-
Tension adjustment
see “Infeed
conveyor, outfeed
conveyor
–
Belt
adjustment”.
Safety devices
Efficiency check
Replace the damaged
components.
-
Reducer filter
Condensation check
Drain condensation.
See “Condensate
drainage”.
Cleaning
Clean with an air jet
and alcohol.
See “Cleaning the
a
ir filter”.
Every 5000 hours
Cutting blade
Efficiency check
Replacement
See “Film cutting
blade replacement”.