103
MAINTENANCE INFORMATION
ENG
7.3. CONDENSATE DRAINAGE
1.
Close the tap (A) and check the level of condensation in the container (B).
2.
Unscrew, if necessary, the valve (C) to drain the condensation.
3.
Push the valve (C) upwards until all condensation is let out.
4.
Tighten the valve (C) again.
7.4. AIR FILTER CLEANING
1.
Unscrew the container (B) with the specific wrench.
2.
Remove the filter, clean it with compressed air and wash it, if necessary, with petrol or trichloroethylene.
3.
Refit the filter and tighten the container (B).