109
FAULT INFORMATION
ENG
Code
Problem
Cause
Solution
E60
Product infeed photocell
alarm
The photocell detects that the
product is not in the correct
position or that the reflector is
not properly aligned.
Remove the product or align
the photocell with the
reflector.
E61
Product outfeed photocell
alarm
The photocell detects that the
product is not in the correct
position or that the reflector is
not properly aligned.
Remove the product or align
the photocell with the
reflector.
E62
“Clamp forward” alarm
Clamp cylinder magnetic
sensors not properly working.
Check and replace the
sensor if necessary.
E64
“Film breakage” alarm
The film has broken or spool
is finished.
Insert the film or replace
spool.
E69
Glued
remote
switch
contacts
Use the counter
Contact the assistance
service
E50
"CanOpen” communication
alarm
Interrupted communication
between PLC and remote
devices.
Check the Can Open
connections from the PLC to