background image

                                     

 

 

                                    

Poollift Delphin 

    

 

 

 

 

 

 

         

_______________________________________________________________________ 

 

Version: February, 2015 

 

 

   

 

 

 

 

MANUAL 

 

AND 

 

OPERATING INSTRUCTIONS

 

 

 

 

 

 

 

 

 

 

                                                                     

_______________________________________________________________ 

                                                                        

 

 

Summary of Contents for Delphin

Page 1: ...llift Delphin _______________________________________________________________________ Version February 2015 MANUAL AND OPERATING INSTRUCTIONS _______________________________________________________________ ...

Page 2: ...ls 3 3 Installation Instructions 4 Fastening possibilities 4 Setting up 4 Installation 4 4 Start up Operation 8 Locking lock 8 Carriage 8 5 Operating 9 6 Diagnostics 9 7 Cleansing and Maintenance 9 8 Packaging Delivery and Storage 10 9 Attachments 11 List of parts 12 Mechanical scheme 13 Instructions for seal and piston replacement 14 Maintenance list 15 ...

Page 3: ...3 Mpa For a maximum load of 120 kg it is necessary to have a water pressure of min 0 4 MPa In most homes the water pump provides the necessary amount of 0 4 MPa The fastening of the Poollift is suitable for different types of swimming pools The Poollift is deliverd with a recessed or a screwed panel Both options can be accomplished with a extended C tube if the distance between the edge of the poo...

Page 4: ...ty anchors or dowels should be used for the fastening If the Poollift has to be dismanteld it is possible to simply unscrew the panel Setting up A minimum water depth of 1050 mm is necessary Furthermore it is important to ensure that the entry point is easily accessible for users and that also a water supply has to be possible When using a standard C tube the center of the panel should be at least...

Page 5: ... the overhanging of the pool edge Setting of the overhanging of the pool edge on the spacer Removal of the screws to fasten the C tube Applying the C tube and screwing it together Inserting the safety ring see first picture into the panel ...

Page 6: ...llift Delphin page 6 Placing the Poollift at the pool edge Implementing the additional pillar and screwing it to the panel using the union nut Attaching the water hose Unhooking the Poollift lock if needed ...

Page 7: ...Poollift Delphin page 7 Mounting the seat into the provided holder Tightening the seat bracket seat height is adjustable Checking the immersion depth lower landing and entry height upper landing ...

Page 8: ...nder downwards to let the air escape from the cylinder 4 Connect the pressure water hose to the valve Always use drinking water for the operation and never water from the pool 5 Adjust the entry height according to the customer s request Locking lock The Poollift can be bolted and locked if it is in the upper landing That way it is protected against unauthorized use ATTENTION The Poollift must be ...

Page 9: ...f the installation The Poollift does not move or too slow upwards Check The pressure water supply must be opened and the pressure water hose must be flawless The valve must be in the end position turned down Appropriate water pressure is necessary There must not be any defect on the seal of the cylinder The Poollift does not move or too slow downwards Check The drain hose must be in good condition...

Page 10: ...eaked out After draining the cylinder keep the cylinder in the upper position If necessary close the Poollift in that position using the lock It is absolutely required to maintain your Poollift regularly How to replace the seals and pistons is described in the the document Instructions for seal and piston replacement 8 Packaging Delivery and Storage In some cases the Poollift will be deliverd disa...

Page 11: ...Poollift Delphin page 11 9 Attachments Attachment 1 List of parts Attachment 2 Mechanical scheme Attachment 3 Instruction for seal and piston replacement Attachment 4 Maintenance list ...

Page 12: ...000 040 carriage 16 B1000 005 C tube 17 B1000 022 cylinder 18 B1000 029 seal not shown 19 B1000 024 upper piston not shown 19A B1000 023 lower piston not shown 20 B1000 004 fastening tube 21 B1000 001 piston rod 22 B1000 057 seat 23 B1000 038 left armrest on order 24 B1000 008 seat frame 25 B1000 030 cover not shown 26 B1000 031 key for cover not shown 27 B1000 015 lower cross connection 28 B1000 ...

Page 13: ...mended type of pressure water hose type MPVC10 14 5 inner diameter of 10mm Operating lever on the entry level as well as on the water lever is easy to reach Seat rotates 90 The fastening of the Poollift is appropriate for different kinds of swimming pools Dual pillar with extended C tube left armrest transport wheels and seat belt on special order 00 VAR IAB ILN Í M AX 200 ARIABILNÍ 0 1220 MM ...

Page 14: ...5 Slide out the upper piston 6 Slide out the upper seal 7 Unscrew three screws from the spacer of the lower piston and slide out the spacer 8 Slide out the lower seal 9 Slide out the lower piston After the optical control exchange the used seals and pistons and put the cylinder back together in reverse Make sure that that the screws in the center of the main tube are in line with each other before...

Page 15: ...ntenance list Installed by ________________________________ Date ____________ This is the maintenance list for your Poollift This document will be filled out by your maintenance technician while maintaining Date Details Installer ...

Reviews: