X: RSSI voltage Unit is mV.
Examples as follows:
If the measured RSSI voltage is 900mV, according to the above formula,
900/20-120 = -75, then the actual received RSSI is-75dBm.
If the measured RSSI voltage is 0.1V, according to the above formula,
100/20-120 = -115, then the actual received RSSI is-115dBm. (Minimum value)
Installation
Transmitter Installation
Control Process
Take FUTABA T12FG as example, T12FG transmits signals to R6203SB, and then
R6203SB transmits the SBUS signal to the signal acquisition system, subsequently
the signal acquisition system transmits signals to T4047NB20, following that
T4047NB20 transmits UHF RF signal to R4047NB20, and R4047NB20 output 18
channels of PWM signals to each servo.
The Installation of RF Part
The antenna can be installed directly to the transmitter's RF interface. You can
also use the RF cable with SMA terminal.