48
Appendix
Operating manual neoTower® Premium L / 03.2017
Product designation
neoTower® 50.0
Standard
High temperature
Calorific value
12.4.7
Supply and exhaust air
Combustion air requirement [m³/h]
183
183
183
Module ventilation flow rate [m³/h]
1,100
1,100
1,100
Total air requirement of module in heat-
producing appliance [m³/h]
1,283
1,283
1,283
Permissible counter-pressure of exhaust air
system max.
(4)
[Pa]
150
150
150
12.4.8
Flue gas
Flue gas temperature
(5)
[°C]
95
100
85
Flue gas mass flow rate - damp [kg/h]
193
193
193
Flue gas volume flow - dry [Nm³/h]
156
156
156
Flue gas counter-pressure max. [Pa]
500
500
500
Flue gas counter-pressure max. in boiler
cascades [Pa]
150
150
150
12.4.9
Dimensions & weight
Dimensions of module L x W x H [mm]
2,180x798x1,670
2,180x798x1,670
2,180x798x1,670
Length [mm]
2,180
2,180
2,180
Width [mm]
798
798
798
Height [mm]
1,670
1,670
1,670
Module capacity [L]
2,905.20
2,905.20
2,905.20
Module surface area [m²]
13.43
13.43
13.43
Weight approx.
(7)
[kg]
1,650 - 1,860
1,650 - 1,860
1,650 - 1,860
12.4.10 Installation location
In accordance with the respective effective heat-producing appliance ordinance
12.4.11 ErP label
ErP energy efficiency label
(6)
n/a
ErP energy usage
(6)
[kWhHs]
158.7
158.7
158.7
ErP efficiency ratio - electrical
ƞ
el,HS
(6)
[%]
31.5
31.5
31.5
ErP efficiency ratio - thermal
ƞ
th,HS
(6)
[%]
53.6
50.4
63.0
ErP efficiency ratio - total
ƞ
total,HS
(6)
[%]
85.1
81.9
94.5
Room controller category
(6)
2.0
2.0
2.0
P ign
(6)
[kW]
0.0
0.0
0.0
P SB electrical power requirement -
standby
(6)
[kW]
0.1
0.1
0.1
123 4
4 Exhaust air (without flue gas) does not have to be extracted “via the roof”
5 At a return flow temperature of <=40
°C
6 In accordance with EU Regulation 811/2013; 813/2013