77
c.
Input the second point on the vertical
plane, and press [ENT].
InputP2
InputP2
P1:
1
1
P2:
2
Meas
List
Stac
d.
Once the plane is defined, the calculated
Sta and dZ values are updated as you
move the telescope. No distance
measurement is required.
STA
:
Horizontal distance from P1 to
the target point along the baseline
dZ: Vertical distance from P1 to the
target point
V-Plane
1/3
STA:
-3.815m
dZ:
-0.153m
* STA: is P1-P2 line
to P1 dist
2/3
V-Plane
2/3
N:
0.711m
E:
3.860m
Z:
-0.516m
* INT of collimator
and plane is XYZ
Press [▼] to display other
pages. As
shown in the right graph.
V-Plane
3/3
HA#
78
°
45
’
19
”
VA#
167
°
30
’
26
”
* Press [ENT] Rec.
e.
To record the point, press [ENT] on any
screen. Input PT and CD and then press
[ENT] in the dialog box shown as the
right graph.
[ENT]
HA:
78
°
45
’
19
”
VA:
167
°
30
’
26
”
SD:
13.333m
PT: 221
CD:
List
Stac
※
1)
About method to input PtID, please refer to “2.8 METHOD TO INPUT PTID”.
7.6 3-PT REFERENCE PLANE (S-PLANE)
Measuring distance and offset values on the slope.