3. ROUTINE MEASUREMENTS
3.1 CAUTIONS FOR DISTANCE MEASUREMENT
After setting up and switching on correctly, the Total Station is immediately ready for measuring.
All shown displays are examples. It is possible that local software versions are different from the basic one.
Example of a possible measuring display:
Display
1/5
HA#
30
°
21
’50”
VA#
273
°
13
’45”
SD#
PT:1
HT:
1.000m
3.2 EDM SETTING
Press [MSR1] or [MSR2] for 1 second to enter each measurement function it is specified.
STEP
OPERATION
DISPLAY
a.
To view the measurement setting, hold
down [MSR1] or [MSR2] for one second.
Here take measurement mode setting in
basic measurement as example.
Display
1/5
HA#
30
°
21
’50”
VA#
273
°
13
’45”
SD#
PT:1
HT:
1.000m
b.
Take the measurement mode specified
on [MSR1] for example. Press
[▲] or
[▼] to move to the item that needs to
be modified, and press [ ] or [ ] to
change the options.
※
1)
[MSR1]/
[MSR2] for 1
second.
<MSR1>
TGT:
Prism
Const:
-30mm
Mode:
Fine[s]
Rec:
All
c.
After setting, press [REC/ENT] to save
the setting and return to last screen.
※
2)
[REC/ENT]
Display
1/5
HA#
30
°
21
’50”
VA#
273
°
13
’45”
SD#
PT:1
HT:
1.000m
※
1) All options in each item in measurement setting:
TGT: Prism, reflector sheet and non-prism (only or reflectorless instrument).
Const: Input prism constant directly (under prism mode). Scale: -999
~
999mm
Mode: Fine[s], Fine [2] ([3]/ [4]/ [5]), Fine[r], Tracking.
Rec: Enter, All, Meas. This mode controls the mode operation of [MSR1]/MSR2] in basic
measurement
function.
If “Enter” is adopted, a screen of “Rec Pt” is displayed to inform the user to check and confirm before data is
recorded.