42
e.
Input the height of instrument, and press
[ENT].
Input the
instrument
height
[ENT]
QuickStn
ST:
123
1
HI:
1.800m
BS:
AZ:
f.
No default PT is assigned to the BS.
Leave this field blank, or enter a BS point
name.
QuickStn
ST:
123
1
HI:
1.800m
BS:
AZ:
g.
The backsight azimuth (AZ) defaults to
zero, but you can change this.
Enter azimuth of
BS
QuickStn
ST:
123
1
HI:
1.800m
BS:
AZ:
h.
To complete the station setup, sight the
BS and press [ENT].
[ENT]
※
1) About the
Split ST setting, please refer to “11.3 setting”.
※
2)
When you press [ENT] in the AZ field, both HA and AZ are reset to the value you have entered.
4.4 HEIGHT TRANSFER (DETERMINING STATION ELEVATION)
This function determines the height of the instrument from measurements to target points with known
heights, in two faces.
After measuring, the new height of station is displayed.
STEP
OPERATION
DISPLAY
a.
In [Stn Setup] press [4] to enter into
height transfer function.
[4]
Stn Setu
1. Known
2. Rese
3. QuickStn
4. Z Coord
5. BS Check