[ 15-29 ]
MZ870 / MZ890 / MZ1070 / MZ1090
(Revision 0.9)
TEST MODE
No.
Data setting
Print drum
changeover
0741
Paper-feed-clutch ON angle
–
Description
Sets the activation angle for the paper feed clutch.
Setting
Setting range: –200 to +200 (–20.0° to +20.0°)
* (<+> for slower ON timing)
Setting unit: 5 (0.5°)
Default: 0 (0°)
0742
Paper-feed-clutch OFF angle
–
Description
Sets the deactivation angle for the paper feed clutch when the paper type is
normal.
Setting
Setting range: –200 to +200 (–20.0° to +20.0°)
* (<+> for slower OFF timing)
Setting unit: 5 (0.5°)
Default: 0 (0°)
0744
Paper Feed Clutch OFF Angle (card)
–
Description
Sets the deactivation angle for the paper feed clutch when the paper type is
<CARD>.
Setting
Setting range: –200 to +200 (–20.0° to +20.0°)
* (<+> for slower OFF timing)
Setting unit: 5 (0.5°)
Default: 0 (0°)
0749
FP Paper Feed Clutch ON Angle
–
Description
Sets the activation angle for the paper feed clutch for proof print.
Setting
Setting range: –100 to +100 (–10.0° to +10.0°) * <+> for slower ON timing
Setting unit: 5 (0.5°)
Default: 0 (0°)
0750
Paper feed reverse-rotation prevention solenoid Activate/Deactivate selection.
–
Description
Activates or Deactivates the Paper feed reverse-rotation prevention solenoid.
Setting
Setting range: 0: Deactivates the solenoid. 1: Activates the solenoid.
Default: 1: Activates the solenoid.
<Paper Feed Pressure Lever must be selected to Card to activate the solenoid.>
0751
Paper feed jam detection angle. (Paper IN)
–
Description
Sets the detection angle for paper feed jam (paper feed IN).
Setting
Setting range: –200 to +200 (–20.0° to +20.0°)
* <+> for slower detection timing
Setting unit: 5 (0.5°)
Default: 0 (0°)
0752
Paper feed jam detection angle. (Paper OUT)
–
Description
Sets the detection angle for paper feed jam (paper feed OUT).
Setting
Setting range: –200 to +200 (–20.0° to +20.0°) * <+> for slower detection
timing
Setting unit: 5 (0.5°)
Default: 0 (0°)
0753
Paper receiving jam detection angle. (Paper IN)
–
Description
Sets the detection angle for paper ejection jam (paper ejection IN).
Setting
Setting range: –500 to +500 (–50.0° to +50.0°) * (<+> for slower detection
timing)
Setting unit: 5 (0.5°)
Default: 0 (0°)
Summary of Contents for MZ1070
Page 2: ...MZ870 MZ890 MZ1070 MZ1090 Revision 0 9 ...
Page 6: ... 2 6 MZ870 MZ890 MZ1070 MZ1090 Revision 0 9 MACHINE SUMMARY MEMO ...
Page 16: ... 2 16 MZ870 MZ890 MZ1070 MZ1090 Revision 0 9 MACHINE SUMMARY MEMO MACHINE SUMMARY ...
Page 24: ... 3 24 MZ870 MZ890 MZ1070 MZ1090 Revision 0 9 MAIN DRIVE SECTION MEMO MAIN DRIVE SECTION ...
Page 32: ... 5 8 MZ870 MZ890 MZ1070 MZ1090 Revision 0 9 SECOND PAPER FEED SECTION MEMO ...
Page 38: ... 14 4 MZ870 MZ890 MZ1070 MZ1090 Revision 0 9 MASTER MAKING SECTION MEMO ...
Page 40: ... 15 6 MZ870 MZ890 MZ1070 MZ1090 Revision 0 9 TEST MODE MEMO ...
Page 86: ... 15 52 MZ870 MZ890 MZ1070 MZ1090 Revision 0 9 TEST MODE MEMO ...
Page 88: ... 16 54 MZ870 MZ890 MZ1070 MZ1090 Revision 0 9 PANEL MESSAGE MEMO ...